top of page

High-Sensitivity Matched Fluxgate Magnetometer Pair


The Paired FG-3+ sensor set delivers two high-precision fluxgate magnetic field sensors with closely matched electrical characteristics, designed for applications requiring balanced dual-sensor performance and reproducibility.

 

Each sensor in the pair is based on the FG-3+ one-axis fluxgate magnetometer, a compact yet highly sensitive magnetic field sensor capable of measuring subtle field variations with precision far beyond typical integrated magnetometers. It is an excellent replacement for legacy Speake & Co. FGM-1 and FGM-3 sensors and is particularly suited for geophysical, industrial, scientific, and embedded applications.

 

Key Specifications:

 

  • Matched sensor pair — aligned for equivalent electrical and magnetic response for use in differential or comparative measurement systems.

  • Sensor type: 1-axis fluxgate magnetometer.

  • Operating range: ±50 microtesla (±0.5 Oe).

  • Output: Robust 5 V square-wave signal; frequency/period proportional to magnetic field strength for easy interfacing with microcontrollers and data acquisition systems.

  • Supply: Single +5 V DC (typical); up to +7 V maximum.

  • Typical supply current: ~12 mA.

  • Output frequency range: ~50 kHz – 120 kHz (period ~8.5 µs to 25 µs across full ±50 µT).

  • Bandwidth: DC to ~20 kHz.

  • Operating temperature: 0 °C – 50 °C.

  • Dimensions: 5.5 cm × 1.5 cm per sensor.

 

Features & Benefits:

 

  • Matched pair ensures consistency: Perfect for gradiometer setups, differential sensing, and noise-cancelling dual-sensor measurements.

  • Exceptional magnetic sensitivity: Far exceeds typical integrated magnetometer solutions for precise anomaly detection.

  • Easy digital interfacing: Frequency-based output makes signal acquisition and processing straightforward on microcontrollers, FPGAs, and data loggers.

  • Low temperature coefficient: Stable performance across temperature variations.

  • Broad application range: From geophysical and archaeological surveys to metal and pipeline detection, traffic monitoring, and magnetic anomaly mapping.

 

Test Report Insights (Independent Evaluation)

Independent testing confirms the FG-3+ output signal’s reliance on the period of its square-wave output and verifies its high sensitivity over a wide range of magnetic fields. Although the raw period-to-field response shows non-linearity in detailed calibration conditions, proper signal processing techniques allow effective conversion and use in precise measurement systems.

Paired FG-3+ Sensors

€102.00Price
Quantity
    bottom of page